DO meter SM-600
DO meter SM-600 - Alat Perikanan

Specifications :
- O² Range : 0.0 to 19.9 mg/l
- O² resolution : 0.1 mg/l
- O² Accuracy : ±1.5% Full Scale
- Calibration : manual on 2 points (zero and slope)
- Temp. Compensation : automatic, from 0 to 30°C
- Probe : MA840 (included)
- Environment : 0 to 50°C / 32 to 122°F; max RH 95%
- Battery Type : 1 x 9V alkaline (included)
- Battery Life : approx. 70 hours of continuous use
- Dimensions : 145 x 80 x 40 mm
- Weight : 220 g (with battery)

DO meter MW-600
DO meter MW-600 - Alat Perikanan

O2 Range : 0.0 to 19.0 mg/L
Resolution : 0.1 (ppm/ mg/L)
Accuracy (@25°C) : ±1.5% Full Scale
Calibration Procedure : Open Air
Positions  : 2 Points Manual (0 - 100%)
Environment : 0 to 50°C / 32 to 122°F; max RH 95%
Battery Type : 9 Volt


DO meter Mi-190
DO meter Mi-190 - Alat Perikanan

Specifications:    
Range O2 : 0.00 to 45.00 mg/L (ppm)
% Saturation O2 : 0.0 to 300%
Temp : -5.0 to 55.0°C / 23.0 to 131.0°F
Resolution  O2 : 0.01 mg/L (ppm)
% Saturation O2 : 0.1%
Temp : 0.1°C / 0.1°F
Accuracy O2 : ±1.5 Full Scale
% Saturation O2 : ±1.5 Full Scale
Temp : ±0.4°C / ±0.8°F
Logging : 50 records, LOG on demand or auto-logging
DO Calibration : automatic, 1 or 2 point at 0% (KM-MA9070) and 100% (in air)
Temperature Compensation : 0.0 to 50.0°C / 32.0 to 122.0°F
Altitude Compensation : 0 to 4000 m; resolution 100 m
Salinity Compensation : 0 to 40 g/L; resolution 1 g/L
DO Probe : KM-MA840/2 with DIN connector (included)

DO meter Mi-605
DO meter Mi-605 - Alat Perikanan

Specifications :
- O2 Range : 0.0 to 45.00 mg/l (ppm)
- % Saturation O2 Range : 0.0 to 300%
- Temp Range : 0.0 to 50.0°C / 32 to 122°F
- O2 Resolution : 0.01 mg/l (ppm)
- % Saturation O2 Resolution : 0.1 %
- Temp Resolution : 0.1°C
- O2 Accuracy : ±1.5% Full Scale
- % Saturation O2 Accuracy : ±1.5% Full Scale
- Temp Accuracy : ±0.5°C
- O2 Typical EMC Deviation : ±0.3 mg/l (ppm)
- % Saturazione O2 Typical EMC Deviation : ±3.5%
- Temp Typical EMC Deviation : ±0.5°C
- DO Calibration : automatic in saturated air
- Temp. Compensation : automatic, from 0 to 50°C / 32 to 122°F
- Altitude Compensation : 0 to 4000 m; 100 m resolution
- Salinity Compensation : 0 to 80 g/L; 1 g/L resolution

DO meter extech II
DO meter extech II - Alat Perikanan

Specifications
Range:
Dissolved oxygen (saturation mode) : 0 to 200.0%
Dissolved oxygen (concentration mode) : 0 to 20.00ppm (mg/L)
Temperature : 32°F to 122°F (0°C to 50°C).
Maximum resolution:
Dissolved oxygen (saturation mode) : 0.1%
Dissolved oxygen (concentration mode) : 0.01ppm (mg/L)
Temperature : 0.1°F/°C.
Basic accuracy:
Dissolved oxygen (saturation mode) : 1.5% FS
Dissolved oxygen (concentration mode) : 0.3ppm (mg/L)
Temperature : ±1.8°F (1°C).
Weight : 3.8 oz.
Dimensions : 1.4” x 6.9” x 1.6”.

DO meter lutron DO 5509
DO meter lutron DO 5509 - Alat Perikanan

DISSOLVED OXYGEN METER  
* Range : 0 to 20 mg/L.  
* ATC. Resolution : 0.1 mg/L.  
* Pocket size, 13 mm LCD.  
* Size : 131 x 70 x 25 mm.




DO meter Lutron DO5510
DO meter Lutron DO5510 - Alat Perikanan

Description:
OXYGEN METER
* -P circuit, LCD with display unit.
* Dissolved oxygen range : 0 to 20 mg/L.
* Max., Min., Memory recall button.
* DO, Oxygen in air, Temp., ATC, Auto Cal., % salt.
* Diaphragms & electrolyte included.
* Probe head with diaphragm set and electrolyte are included.
* Size : 180 x 72 x 32 mm. RS-232

DO meter adwa AD630
DO meter adwa AD630 - Alat Perikanan

Professional IP67 Waterproof Portable D.O Meter (Dissolved Oxygen)
Oxygen Range: 0.00 to 45.00 mg/L; %
Oxygen Saturation Range: 0.0 to 300.0%,
Temp. Range: 0.0 to 50.0 °C,
Accuracy: ± 1% f.s, ± 0.5 °C;
Resolution: 0.01 mg/L, 0.1%, 0.1°C
Features: ATC, Auto Altitude Compensation, Auto Salinity Compensation
Supplied with: in carton box, AD8001/3 galvanic DO probe with built-in temperature sensor, spare membrane with O-ring , AD9551 serial communication cable, 1.5V AA alkaline battery (4 pcs), user manual .

Do meter Horiba OM-51
Do meter Horiba OM-51 - Alat Perikanan

OM-51-02 - RS232C printer output

Measurement Method
Dissolved Oxygen : Diaphragm galvanic battery method
Saturation Oxygen : Dissolved Oxgen conversion
Oxygen : Dissolved Oxgen conversion
Measurement Range
Temperature : 0.0 ~ 100.0: Resolution 0.1:
Dissolved Oxygen : 0.00 ~ 19.99mg/L Resolution 0.01mg/L
Saturation Oxygen : 0.0 ~ 199.9% Resolution 0.1%
Oxygen : 0.0 ~ 50.0% Resolution 0.1%
Repeatability
Temperture : ±0.1: ±1digit
Dissolved Oxygen : ±0.1mg/L ±1digit
Power Supply : DC3V (LR6 dry cell battery)
Option : AC adapter
Mass : approx. 300g 

Web Officer

Kami siap membantu Anda

 

Karya Mitra Mulia

Jln. Ring Road Utara No. 134 Taman Yasmin VI, Bogor, Indonesia

  • Tel: 0251-7543316
  • Fax: 0251-7543 281
  • Email: k555777888@yahoo.com 